Can the energy of moving blood reveal risk that conventional cardiac MRI does not fully capture? A new prospective multicenter study by Wang and colleagues examines this question in nonischemic dilated cardiomyopathy (DCM). Published in Circulation: Cardiovascular Imaging on November 18, 2026, the study places left ventricular blood-flow kinetic energy in a clinically meaningful context: subsequent heart failure events.
What does 4D flow MRI measure?
Unlike ejection fraction, which summarizes the proportion of ventricular blood ejected per beat, 4D flow MRI measures the three-dimensional velocity field over the cardiac cycle. Blood-flow kinetic energy (KE) can be calculated as the sum of ½ρv²ΔV over the ventricular blood pool, where ρ is blood density, v is velocity magnitude and ΔV is voxel volume. Indexing KE to end-diastolic volume (KEiEDV) accounts for ventricular size, although it does not eliminate all effects of remodeling or loading conditions. Peak E-wave KE characterizes early diastolic filling, whereas peak systolic KE describes the systolic phase of blood motion.
A prospective study of 675 patients with DCM
The investigators enrolled 675 adults with DCM across three centers and 80 matched healthy volunteers. Over a median of 42 months, 58 patients (8.6%) reached a composite outcome of heart failure-related death, unplanned heart failure hospitalization or cardiac transplantation.
How the 4D flow measurements were obtained
Whole-heart 4D flow was acquired on Philips Ingenia Elition and Siemens MAGNETOM Vida 3T systems. The investigators used CVI42, background offset and aliasing correction, static LV segmentation on magnitude images and phase-specific mitral and aortic valve tracking with manual corrections. Post-processing took approximately 30 minutes per patient. Interobserver and intraobserver ICCs for KE parameters exceeded 0.85.

Lower kinetic energy was associated with worse outcomes
Both peak systolic and peak early-filling KEiEDV were lower in DCM, particularly among patients who later experienced an event. Associations persisted in adjusted analyses accounting for LVEF, NT-proBNP, extracellular volume fraction and late gadolinium enhancement extent. The investigators also reported incremental prognostic information beyond clinical and conventional CMR markers.
Kinetic energy and heart failure events
Adjusted hazard ratios (95% confidence intervals)
Does 4D flow improve risk prediction?
Adding both KE peaks to the model containing LVEF, log NT-proBNP, LGE extent and ECV increased Harrell’s C-index from 0.71 to 0.81 (Table 4). The baseline model containing LVEF and log NT-proBNP alone had a C-index of 0.64. Net reclassification improvement was 0.13 (95% CI 0.09–0.17; P<0.001), and integrated discrimination improvement was 0.03 (95% CI 0.01–0.07; P=0.021). These estimates describe discrimination within the study cohort, not independently validated clinical performance.
Exploratory analyses suggested that early diastolic KE was more strongly associated with events in patients with LVEF >35%, whereas systolic KE appeared more informative at LVEF ≤35%. These subgroup observations should not be interpreted as established differences without formal interaction testing.

Why this matters for cardiovascular imaging
The important distinction is that these measurements are being evaluated as outcome-related biomarkers, rather than simply as features that separate patients from healthy volunteers. An impaired early-filling KE peak may reflect altered intracavitary blood motion, but it should not be interpreted as a direct measurement of relaxation, filling pressure or myocardial energetics. Similarly, low systolic KE is not synonymous with low ejection fraction.
This work raises an interesting translational question: could phase-specific flow measures complement tissue characterization and ventricular function when identifying higher-risk patients? Reproducibility across scanners, segmentation strategies, temporal resolution and normalization methods will be essential before such metrics can become routinely interpretable.
What remains to be established?
These associations do not establish causation or a treatment target. The main study reports the HRs as per 1% increase, although KE is expressed in µJ/mL; the exact scaling should be checked against the supplemental methods before interpreting a unit-specific effect. Important limitations include manual post-processing time, residual effects of arrhythmia and scanner vendor, incomplete coronary angiographic assessment, and lack of systematic genetic characterization. External validation and clinically actionable thresholds are still needed.
Related research resources
- 4D flow MRI E/A reference values: explore published early-to-late filling measurements, including kinetic energy.
- Cardiac MRI structure and function reference values: conventional ventricular volumes, function and strain.
- Myocardial tissue characterization reference values: T1, T2 and ECV.
Original publication
Wang W, Wang J, Zhu R, et al. Prognostic Value of Left Ventricular Kinetic Energy Assessed by 4D Flow CMR in Dilated Cardiomyopathy: A Prospective Multicenter Cohort Study. Circ Cardiovasc Imaging. Published online November 18, 2026. doi: 10.1161/CIRCIMAGING.126.020208. PubMed.
Source note: This commentary is based on the full article (published online November 18, 2026; January 2027 issue, volume 20, e020208). The article is available under the CC BY-NC-ND 4.0 license. The original forest plot above is an independently prepared visualization of reported numerical estimates.