Pulse Wave Velocity
Explore age-related PWV values and compare published clinical populations against a muted healthy-reference background. Values are study summaries, not individual participant data or diagnostic thresholds.
What is pulse wave velocity (PWV)?
Pulse wave velocity measures how fast the arterial pressure wave travels, in meters per second (m/s). It is not the same as blood flow velocity. A faster pulse wave generally reflects a stiffer arterial system, although PWV also changes with blood pressure, age, the arterial segment examined, and how transit time is calculated.
What is a normal PWV for a given age? No single normal value applies across all techniques or populations. The healthy-reference studies below illustrate age-related PWV patterns. Use the method filters to compare values obtained over similar arterial paths, then choose a clinical population on the left to overlay its reported PWV values against the faded healthy-reference curves.
Healthy reference
Published summaries plotted by age and method.
Hover over a point or line for study details. Click to dim or restore that study.
Values behind the plot
Rows update with population and method. Each paper is listed once per selection.
| Ref. | Group / measurement | Age (years) | PWV (m/s) | N | Details |
|---|---|---|---|---|---|
| [1] | Healthy 4D flow MRI | <30 | 4.90 Median | 16 | Age x-position approximated from age band |
| Healthy 4D flow MRI | 30–40 | 5.40 Median | 20 | Age x-position approximated from age band | |
| Healthy 4D flow MRI | 40–50 | 6.30 Median | 20 | Age x-position approximated from age band | |
| Healthy 4D flow MRI | 50–60 | 7.30 Median | 24 | Age x-position approximated from age band | |
| Healthy 4D flow MRI | 60–70 | 7.80 Median | 19 | Age x-position approximated from age band | |
| Healthy 4D flow MRI | >70 | 8.50 Median | 25 | Age x-position approximated from age band | |
| [2] | Healthy 2D PC MRI | 45–50 | 5.40 Mean | — | Healthy subgroup (n = 397 total); 95% CI 5.3–5.6 |
| Healthy 2D PC MRI | 50–55 | 5.80 Mean | — | Healthy subgroup (n = 397 total); 95% CI 5.6–5.9 | |
| Healthy 2D PC MRI | 55–60 | 6.10 Mean | — | Healthy subgroup (n = 397 total); 95% CI 5.8–6.5 | |
| Healthy 2D PC MRI | 60–65 | 6.80 Mean | — | Healthy subgroup (n = 397 total); 95% CI 6.5–7.0 | |
| [3] | Healthy Aorta-targeted | 43.2 ± 10.1 | 6.77 ± 1.28 Mean ± SD | 38 | — |
| Healthy Whole-heart | 43.2 ± 10.1 | 6.89 ± 1.31 Mean ± SD | 38 | — | |
| [4] | Healthy GRAPPA R=2 | 27.8 ± 4.9 | 4.91 ± 0.63 Mean ± SD | 16 | — |
| Healthy CS R=7.7 | 27.8 ± 4.9 | 5.43 ± 0.86 Mean ± SD | 16 | — | |
| [5] | Healthy cfPWV | <30 | 6.20 Mean | — | Age x-position approximated from age band |
| Healthy cfPWV | 30–39 | 6.50 Mean | — | Age x-position approximated from age band | |
| Healthy cfPWV | 40–49 | 7.20 Mean | — | Age x-position approximated from age band | |
| Healthy cfPWV | 50–59 | 8.30 Mean | — | Age x-position approximated from age band | |
| Healthy cfPWV | 60–69 | 10.30 Mean | — | Age x-position approximated from age band | |
| Healthy cfPWV | >70 | 10.90 Mean | — | Age x-position approximated from age band | |
| [6] | Healthy 5.80 [4.91–7.19] | Not reported for healthy subgroup | 5.80 Median [IQR] | 139 | Age 66.5 belongs to full MRI cohort, not healthy subgroup; table only |
How is pulse wave velocity measured?
In principle, pulse wave velocity (PWV) equals the pulse-wave travel distance divided by the corresponding transit time. Both the arterial path length and the time difference between waveforms must be defined. The wave’s foot, cross-correlation of waveform shapes, and other timing features can yield different transit times, even for similar source data. Blood pressure, age, temporal resolution, and the region measured can also influence the value.
4D flow MRI
4D flow MRI uses time-resolved three-dimensional velocity measurements to sample aortic flow waveforms at multiple locations. Regional or global aortic PWV can be estimated by relating the pulse-wave transit time to a defined distance along the vessel. The analysis may use waveform features, cross-correlation, or transit-time regression. Temporal resolution, spatial sampling, path definition, and reconstruction settings can influence the estimate. Values should therefore be interpreted using the acquisition and analysis method used to obtain them.
Because aortic PWV depends on the shape and timing of flow waveforms, the estimated value may change with MRI acceleration, reconstruction, and transit-time analysis. For an example, see GRAPPA versus compressed sensing: how acquisition and PWV algorithm affect the estimate.
2D phase-contrast MRI
2D phase-contrast MRI samples flow at selected imaging planes, such as locations in the ascending and descending aorta. PWV is typically estimated from the distance between the sampling locations and a difference in waveform arrival time. Methods may use the waveform foot or another reproducible timing feature. Measurements spanning a longer aortic segment are not necessarily equivalent to local arterial measurements. Age, blood pressure, plane placement, and timing definitions are relevant when choosing a reference population.
Carotid-femoral PWV (cfPWV)
Carotid-femoral PWV is typically determined by noninvasive peripheral arterial recordings and the estimated carotid-to-femoral travel distance. It is commonly used to assess central arterial stiffness, yet its path differs from aortic MRI. Values from cfPWV, 2D PC MRI, and 4D flow MRI should not be pooled into one normal limit or directly substituted for one another.
What is a normal pulse wave velocity by age?
PWV generally increases with age as arterial mechanical properties and vascular loading change over the lifespan. However, a single age-specific PWV value cannot serve as a universal reference: the expected range depends on the vascular path, measurement technique, blood pressure, and characteristics of the study population. This page brings together published healthy-population values from 4D flow MRI, 2D PC MRI, and carotid-femoral measurements. Use the method filters and the age labels in the table to explore patterns within comparable techniques rather than treating all values as one clinical threshold.
The plotted x coordinate for a reported age band is an approximate representative position, not the age of every participant. The line connects age categories from one publication; it does not represent longitudinal follow-up of the same individuals. Points represent cohort means or medians, rather than individual measurements. Error bars indicate reported standard deviation when available; confidence intervals and interquartile ranges are described in the table.
Comparing healthy references with clinical populations
When you select a pathology on the left, its reported values appear in color and the healthy-reference values remain visible in pale gray. This helps orient the literature, but the graph is not an age-, sex-, blood-pressure-, and method-matched case-control comparison. Differences in vascular path, waveform analysis, recruitment, blood pressure, or study age distribution may explain some of the apparent separation. Use the measurement-method tabs when comparing a particular pathology with healthy observations.
Values reported for local ascending or descending aortic PWV are retained in the corresponding table rather than overlaid on global or regional transit-time PWV curves, because they do not necessarily represent comparable physiological or methodological quantities.
PWV in selected clinical populations
Hypertension and elevated cardiovascular risk
Arterial blood pressure affects the mechanical loading of the arterial wall and can influence measured PWV. It is useful to distinguish the contribution of the current pressure load from longer-term structural changes in the arteries. The hypertension-related data are organized by treatment group and follow-up timepoint. In the interactive chart, the selected timepoint displays measured cfPWV; additional load-dependent measurements remain in the corresponding table for context. These values describe the included groups and are not, by themselves, evidence of a treatment effect relative to the healthy-reference cohorts.
Overweight without type 2 diabetes
Body composition, blood pressure, and other cardiometabolic factors may be associated with differences in arterial stiffness. PWV values in overweight populations are also sensitive to the measurement path and method. The chart provides a method-aware view of published cohort summaries, while the table retains measurements obtained with different techniques. Local aortic values are shown separately in the table rather than directly overlaid on global or regional PWV values.
Type 2 diabetes
In people with type 2 diabetes, PWV may reflect the combined influence of age, blood pressure, metabolic health, vascular remodeling, and associated cardiovascular or kidney risk factors. Differences from a healthy reference curve should not automatically be attributed to diabetes alone. The plot highlights the selected population’s values, and the table identifies the acquisition method and summary statistic. Comparisons are most useful when age and measurement methods are similar, while remembering that these are results from separate published cohorts.
Bicuspid aortic valve (BAV)
Bicuspid aortic valve is associated with differences in valve morphology, aortic anatomy, and flow patterns that can be relevant when investigating vascular function. Aortic PWV may also depend on the region sampled and the 4D flow MRI acquisition and analysis method. The interactive figure displays the available cohort-level measurements alongside faded healthy-reference observations. Any difference should be interpreted in the context of vessel geometry, blood pressure, valve function, and study design rather than as a stand-alone diagnostic threshold.
Reading and interpreting the figures
Methods are colored consistently across the graph: red for 4D flow MRI, teal for 2D PC MRI, and blue for carotid-femoral PWV. The displayed statistics may be a mean, median, or mean ± standard deviation, as reported by each publication. Sample sizes refer to the relevant cohort when known. Error bars are not inferred from a different statistic. The left menu changes the highlighted study population, and the table beneath the plot retains method-specific measurement details and links each study to the shared numbered reference list.
For a deeper discussion, see Pulse Wave Velocity: Structural and Load-Dependent Arterial Stiffness, the 4D flow MRI research hub, and the 4D flow MRI E/A reference values.
Frequently asked questions about PWV
Does higher PWV necessarily indicate vascular disease?
Not by itself. PWV tends to rise with age and arterial pressure, and measurement methods produce different estimates. Any clinical interpretation should use technique-specific reference data and patient context.
Can MRI-derived PWV and cfPWV be directly compared?
They measure propagation over different vascular paths and often use different transit-time methods. The shared graph provides methodological context rather than a clinical conversion between techniques.
Why are some PWV values included in the table but not on the graph?
Some publications lack a suitable subgroup-specific age for plotting; others report local rather than regional or global PWV. Including these values only in the table avoids suggesting age or methodological equivalence that was not reported.
How to interpret PWV
PWV = path length / pulse transit time. Values depend on measurement location, blood pressure, reconstruction, and transit-time algorithm. 4D flow, 2D PC MRI, and carotid-femoral methods must not be treated as equivalent thresholds.
Published averages or medians describe study cohorts. An apparent difference from the healthy background does not establish a pathology effect without age, blood pressure, and method matching.
The table preserves method-specific results when a cohort has multiple acquisitions. Local aortic PWV is not superimposed on regional or global PWV curves. When a publication does not provide an age summary for the specific subgroup shown, the PWV is included in the table without assigning an unsupported age position on the graph.
Additional context: Structural and load-dependent arterial stiffness · 4D flow MRI research.
References
Publications are listed once in this numbered reference list. The same number is used wherever a source contributes measurements to more than one population or method.
- [1] Johnson, Ethan MI, et al. “Global aortic pulse wave velocity is unchanged in bicuspid aortopathy with normal valve function but elevated in patients with aortic valve stenosis: insights from a 4D Flow MRI study of 597 subjects.” Journal of Magnetic Resonance Imaging 57.1 (2023): 126-136. View paper ↗
- [2] van Hout, Max J., et al. “Normal and reference values for cardiovascular magnetic resonance-based pulse wave velocity in the middle-aged general population.” Journal of Cardiovascular Magnetic Resonance 23.1 (2021): 46. View paper ↗
- [3] Dushfunian, David, et al. “Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve.” The International Journal of Cardiovascular Imaging 41.1 (2025): 137-149. View paper ↗
- [4] Wang, Bingyi, et al. “Highly Accelerated Aortic 4D Flow MRI: Implications for Pulse Wave Velocity Measurements.” Journal of Magnetic Resonance Imaging (2025). View paper ↗
- [5] Reference Values for Arterial Stiffness’ Collaboration. “Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors:‘establishing normal and reference values’.” European heart journal 31.19 (2010): 2338-2350. View paper ↗
- [6] Riedl, Katharina A., et al. “Associations between cardiovascular risk factors and diseases with aortic pulse wave velocity and aortic distensibility: magnetic resonance imaging in the Hamburg city health study.” Clinical Research in Cardiology 115 (2026): 1389-1399. View paper ↗
- [7] Pewowaruk, Ryan, et al. “Effects of Blood Pressure Control on Arterial Stiffness Mechanisms in SPRINT: A Randomized Controlled Trial.” Hypertension 82.6 (2025): 1004-1011. View paper ↗
- [8] Smith, Andrew, et al. “Aortic pulse wave velocity and albuminuria in patients with type 2 diabetes.” Journal of the American Society of Nephrology 16.4 (2005): 1069-1075. View paper ↗
- [9] Abushamat, Layla A., et al. “Obesity dominates early effects on cardiac structure and arterial stiffness in people with type 2 diabetes.” Journal of hypertension 41.11 (2023): 1775-1784. View paper ↗
- [10] Kodithuwakku V, Breslin M, Hersant J, et al.; Youth Vascular Consortium. “Establishing Reference Values for Pulse Wave Velocity in Young People: The Youth Vascular Consortium.” Hypertension. 2025. DOI: 10.1161/HYPERTENSIONAHA.125.25007. SphygmoCor tonometry cfPWV, modeled 50th percentile by age and sex (5–39 years; Table 3, n = 4,753). View paper ↗
- [11] Harloff A, Mirzaee H, Lodemann T, et al. “Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance – a population-based study.” J Cardiovasc Magn Reson. 2018;20:43. Table 3, 126 participants ages 20–79; sex-specific group means ± SD. This general-population study was not restricted to strictly healthy adults. View paper ↗.
- [12] Voges I, Jerosch-Herold M, Hedderich J, et al. “Normal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study.” J Cardiovasc Magn Reson. 2012;14:77. Table 10, age- and sex-specific LMS model M (median / P50), ages 3–28 represented here from the original sample aged 2.3–28.3 years (n = 71 total). View paper ↗.